Specification - Services Actuators
In this group, all actuators present in the living area of the camper are collected. These specifications allow controlling relays and dimmers but also estimating the power consumed.
Name | Type |
---|---|
Switch Low 1-N | BooleanAction |
Switch Low Avg Current | RangeAction |
Switch Low Max Current | RangeState |
Switch High 1-N | BooleanAction |
Switch High Avg Current | RangeAction |
Dimmer Low 1-N | RangeAction |
Dimmer Low Avg Current | RangeAction |
Dimmer Low Max Current | RangeState |
Dimmer High 1-N | RangeAction |
Dimmer High Avg Current | RangeAction |
The specifications of actuators include information on their load capacity and activation time. In addition, actuators differ in their ability to handle different power ranges (high and low). High-power actuators are used to control systems that require a large amount of energy, such as heating and ventilation. Low-power actuators are used to control systems that require less energy, such as lighting.
The pillars * Low Max Current
specifies the average current that an actuators
type can safely handle.
Specs details
Services > Actuators
Switch Low 1-N: BooleanAction
Description | Multiple binary actuators for low consumption services like relays (true is on, false is off). | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Alias |
|
Services > Actuators
Switch Low Avg Current: RangeAction
Description | Avg current consumed by services connected to low consumption switches, set by the user and in Amperes | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Unit | Ampere | |||||||||||||||||||||
Alias |
|
Services > Actuators
Switch Low Max Current: RangeState
Description | Maximum current supported by low consumption switches, in Amperes | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Unit | Ampere | |||||||||
Alias |
|
Services > Actuators
Switch High 1-N: BooleanAction
Description | Multiple binary actuators for high consumption services like relays (true is on, false is off). | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Alias |
|
Services > Actuators
Switch High Avg Current: RangeAction
Description | Avg current consumed by services connected to high consumption switches, set by the user and in Amperes | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Unit | Ampere | |||||||||||||||||||||
Alias |
|
Services > Actuators
Dimmer Low 1-N: RangeAction
Description | Multiple dimmerable (0-100%) for low consumption services actuators like dimmers | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Unit | Percent | |||||||||||||||||||||
Alias |
|
Services > Actuators
Dimmer Low Avg Current: RangeAction
Description | Avg current consumed by services connected to low consumption Dimmer, set by the user and in Amperes | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Unit | Ampere | |||||||||||||||||||||
Alias |
|
Services > Actuators
Dimmer Low Max Current: RangeState
Description | Maximum current supported by low consumption Dimmer, in Amperes | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Unit | Ampere | |||||||||
Alias |
|
Services > Actuators
Dimmer High 1-N: RangeAction
Description | Multiple dimmerable (0-100%) for high consumption services actuators like dimmers | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Unit | Percent | |||||||||||||||||||||
Alias |
|
Services > Actuators
Dimmer High Avg Current: RangeAction
Description | Avg current consumed by services connected to high consumption Dimmer, set by the user and in Amperes | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Unit | Ampere | |||||||||||||||||||||
Alias |
|